Option 40: Trouble Beeps 
(Default = on)
Determines whether the panel, X10, and hardwire interior sirens sound 
six beeps every minute when a trouble condition occurs (on) or not 
(off). The following conditions cause trouble beeps:
• AC power failure (when Option 24 is on)
• Low CPU battery
• Sensor failure (supervisory)
• Sensor trouble (i.e. low battery, tamper, etc.)
• Fail to communicate
• Restoration of Power (if no DTIM installed)
• No Activity timer has timed out. Trouble beeps continue for 5 min-
utes and if the panel does not see activity, trouble beeps stop and 
the panel reports the no activity to the central station.
Trouble beeps can be silenced by arming or disarming the system, or 
by pressing the STATUS button. Trouble beeps resume 4 hours later if 
the trouble condition is not cleared.
Note  
For UL listed systems, Trouble Beeps must be on.
¾To turn on Trouble Beeps, press:
1. Add
2. Option #
3. 40
4. DONE
¾
To turn off Trouble Beeps, press:
1. Delete
2. Option #
3. 40
4. DONE
Option 41: Chime Voice 
(Default = off)
Determines whether the panel announces the sensor number and name 
(on) or only sounds beeps (off), when the CHIME Doors or CHIME 
Special Motion features are on and sensors in groups 10, 13, and 25 are 
tripped while the system is disarmed.
¾
To turn on Chime Voice, press:
1. Add
2. Option #
3. 41
4. DONE
¾
To turn off Chime Voice, press:
1. Delete
2. Option #
3. 41
4. DONE
Option 42: Speaker Level 
(Default = 8)
Sets the volume of voice messages from the panel 
speaker.
The volume can be set from 1 (lowest) to 8 (high-
est). Resetting this option returns the setting to 
the default value.
This option returns to the default setting (8) when 
deleted.
¾
To set Speaker Level, press:
1. Add
2. Option #
3. 42
4. Use the numbered keys to enter 1 - 8.
5. DONE
¾
To reset Speaker Level (return to default), press:
1. Delete
2. Option #
3. 42
4. DONE