Simon Security System
74
06 Downloader Phone Number Off Off 26 digits U1
07 Account Number 00000 00000 0 - FFFFFFFFFF U1 U2
08 Phone Lock Off Off On/Off U1
09 Downloader Code 12345 12345 00000-99999 U1
10 Entry Delay (must be 45 seconds or less for UL
listed systems)
030 sec 005 sec 005-254 sec
030-254 if Option 69
is added
U1 U2
11 Exit Delay (must be 60 seconds or less for UL
listed systems)
060 sec 005 sec 005-254 sec
045-254 if Option 69
is added
U1 U2
12 Phone 1 Reports (must be 00 or 01 for UL listed
systems)
00 Off 00-10 U1
13 Phone 2 Reports Off Off 00-10 U1
14 DTMF On Pulse On/Off U1 U2
15 No Activity Report Off Off 02-24 hrs U1 U2
16 Auto Phone Test (must be set to 001 for UL listed
systems)
Off Off 001-254 days U1 U2
17 Dialer Delay 030 Off 005-254 sec
015-045 is Option
69 is added
U1 U2
18 Alarm Cancel 006 Off 006-255 min U1 U2
19 RF Timeout (SUPSYNC) (must be set to less than
04 for UL 985 & 1635 Listed systems, or less than
24 for UL 1023 Listed systems
12 hrs 12 hrs 02-36 hrs U1 U2
20 Manual Phone Test On Off On/Off U1 U2
21 Opening Reports Off Off On/Off U1 U2
22 Closing Reports Off Off On/Off U1 U2
23 Force Armed Report Off Off On/Off U1 U2
24 AC Power Failure Report (must be added for UL
listed systems)
Off Off 005-254 min U1 U2
25 CPU Low Battery Report
(must be added for UL listed systems)
On Off On/Off U1 U2
26 Fail to Communicate (must be added for UL listed
systems)
On Off On/Off U1 U2
27 Ring/Hang/Ring 1 Off 1-7 U1 U2
28 No Delay from Key Chain Touchpad Off Off On/Off U1 U2
29 Panel Piezo Alarms (must be added for UL listed
systems OR a siren must be connected)
On Off On/Off U1 U2
30 Panic Alarms On Off On/Off U1 U2
31 Downloader Enable On Off On/Off U1 U2 M
32 300 Baud Central Station Communications On 110 Baud On/Off U1 U2
33 Audio Verification Off Off On/Off U1 U2
34 Fail to Open Off Off 12:00 Midnight -
11:59 PM
U1 U2
35 Fail to Close Off Off 12:00 Midnight -
11:59 PM
U1 U2
36 Sensor Activated Light Lockout Start Time Off Off 12:00 Midnight -
11:59 PM
U1 U2 M
Opt. #
Function Default Delete Range Who Can
Change:
Installer
Settings