Zoom20/30/35 Pro | 28Settings
Sector Beep On Sector Beep sounds at right angles (0°, 90°, 180°, 270° or 0,
100, 200, 300 gon).
1)No beep.
2)Fast beep; from 95.0 to 99.5 gon and
105.0 to 100.5 gon.
3)Permanent beep; from 99.5 to 99.995
gon and from 100.5 to 100.005 gon.
Off Sector Beep is deactivated.
Setout Beep On The instrument beeps when the distance from the current posi-
tion to the point to be staked is 0.5 m. The closer the prism is
to the point to be staked the faster the beeps will be.
Off Beep is deactivated.
Screen ill. 20% to 100% Sets the screen illumination in 20% steps.
Crossh ill. Off to 100% Sets the illumination level of the crosshairs in 20% steps.
Heating On The display heater is activated.
Off The display heater is deactivated.
The display heater is automatically activated when the display illumination is on and
the instrument temperature is 5°C. This function is only available for Zoom20 Pro.
Data Output Sets the location for data storage.
Int. Memory All data is recorded in the internal memory.
Interface Data is recorded via the serial interface or the USB device port,
depending on the port selected in the COMMUNICATION
SETTINGS screen. This Data Output setting is only required if
an external storage device is connected and measurements are
started at the instrument with MEAS/REC or ALL. This setting is
not required if the instrument is totally controlled by a data
logger.
GSI-Format Sets the GSI output format.
GSI 8 81..00+12345678
GSI 16 81..00+1234567890123456
Mask Sets the GSI output mask.
Mask1 Pt, HA, VA, sDIST, ppm+mm, TgtHGT, Instr.h.
Mask2 Pt, HA, VA, sDIST, E, N, Z, TgtHGT.
Mask3 StationID, E, N, Z, Instr.h. (Station).
StationID, Ori, E, N, Z, Instr.h. (Station Result).
Pt, E, N, Z (Control).
Pt, HA, VA (Set Azimuth).
Pt, HA, VA, SD, ppm+mm, TgtHGT, E, N, Z (Measurement).
Code Saving Sets if the codeblock is saved before or after the measurement. Refer to "8.1 Coding".
Language Sets the chosen language. The current loaded language(s) are shown.
A selected language can be deleted by pressing DelLng. This function is available if
more than one language is installed, and the selected language is not the chosen
operating language.
Lang. Choice If multiple languages are loaded, a screen to choose the language can be shown
directly after switching on the instrument.
On The language screen is shown as the startup screen.
Off The language screen is not shown as the startup screen.
Touch Screen Available for Color&Touch display only.
On The touch screen is activated.
Off The touch screen is deactivated.
Press Calib. to calibrate the touch screen. Follow the instruc-
tions on the screen.
Field Description