Basic Configuration
182
Ethernet Tally Configuration
The GV K-Frame XP system provides all the tally data needed by the Ethernet tally client.
Typically, the only user-defined selection for Ethernet tally from the switcher is the on-air
Program M/E. PGM/PST is the default on-air tally Program M/E, however any licensed M/E
can be defined as Program. Sources are on or off air based on the Program M/E selection.
Configure the On-Air Tally Program M/E
The default on-air Program M/E is PGM/PST.
1 Select Eng Setup, Switcher Tally, On Air Tally.
2 Select an available (licensed) M/E as the on-air tally Program M/E, for example ME 1,
ME 2, Aux, etc.
Configure the GV Switcher Ethernet Tally System Interface
The switcher system must be configured to interface with third party Ethernet Tally
systems. An initial tally client port selection can help ensure a successful connection.
1 Configure the Ethernet Tally interface IP Address:
a In the Eng Setup, Ports & Devices menu, select the
Tally Ports tab.
b In the Tally Contribution pane, select an Ethernet Tally IP Address data pad and
enter the IP address for an Ethernet Tally system in the pop-up keypad and press
Enter.
2 Select the adjacent Enable button (highlights green when on).
Note: When the connection is enabled, the Connection Status LED turns
green.
3 At the tally client, set the connection to Port 2012 to establish the initial connection
between the GV Switcher and Ethernet Tally systems.
4 At t
he tally client, set the connection to Port 2012 to establish the initial connection
between the GV Switcher and Ethernet Tally systems.