EasyManua.ls Logo

GRASS VALLEY KAYENNE - Grass Valley Switcher Device Monitoring by SNMP; K-Frame SNMP Monitoring; Control Panel SNMP Monitoring; GV Korona Control Panel SNMP Monitoring

GRASS VALLEY KAYENNE
389 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
338
Grass Valley Switcher Device Monitoring by SNMP
Grass Valley K-Frame Family of switchers support monitoring of the devices and device components shown
in the following tables. SNMP provides reporting for each board of the same type, for example M/E,
Modular I/O input, Modular I/O output, etc.
Note: Only the capabilities described in this document are supported. For detailed information about each
supported item, please refer to the MIBs
Supported K-Frame Video Processor SNMP Monitoring
System Information
High level information regarding the Video Processor Frame including operating
system, name, location, serial number, software revision and high level frame state.
Module
Each plug in board slot in the Frame is a module (Controller, M/E or eDPM).
Information is provided regarding the board plugged into the slot and the current
state of the slot.
Power Supply (Up to 3)
Reports power failure if a power supply fails or is not present.
Thermal
High level temperature and fan status for the entire system. If a failure is reported
here then look at Fans or Temperature Sensor categories for details
Fans
Detailed speed and status for each fan in the frame. Five fans are on the compact
frame and one fan in the standard frame. Typically inspected if Thermal category is
reporting a cooling problem.
Temperature Sensors
Detailed information from each monitored temperature sensor on the Frame.
Typically inspected if Thermal category is reporting a cooling problem.
Video Sync
Status of external video reference signal and what type of signal is present.
Network Configuration
Data
IP address, Gateway and Netmask settings for external facing network interfaces.
Supported K-Frame Control Panel SNMP Monitoring
Fan
Kayenne: PCU has three fans
Karrera: 2-M/E Control Panel has one fan, 3-M/E has two fans.
Korona: One Fan
Power Supply
Will report power failure if a power supply is not present or not plugged in.
Temperature
Kayenne: One ambient temperature, one on CPU.
Karrera: One ambient temperature, one on the Panel Processor FPGA, one on CPU.
Korona: One ambient temperature, one on the Panel.
Modules
Status change traps are sent when a module is connected or disconnected.
GV Korona Control Panel
GV Korona can be monitored separately, using the standard built-in Windows SNMP capabilities
and a third-party NMS. No unique Grass Valley MIB entries or traps are available.
Menu Panel Processor
The Menu Panel Processor (the PC running the Menu application) can be monitored separately,
using the standard built-in Windows SNMP capabilities and a third-party NMS. No unique Grass
Valley MIB entries or traps are available.

Table of Contents

Other manuals for GRASS VALLEY KAYENNE

Related product manuals