Maintenance
306
Control Panel IP Information
2 Select Clear NV.
3 Select the
Clear NV button. A Clear NV Files screen will appear.
4 Leave the
Reboot when complete box filled and click OK.
5 NV Memory will be cleared and the Menu or Frame will be rebooted.
Restoring Multiple Control Panels
If your GV Switcher system has multiple Control Panels connected to the same Frame (PCU
Frame for Kayenne), the Clear NV process will clear settings for all the connected panels.
Because separate Panel Prefs exist for each Control Panel, you will need to restore each
Control Panel’s configuration files individually.
Control Panel IP Information
After a panel processor board replacement, the Video Processor Frame IP address will need
to be re-entered into the Control Panel.
Kayenne/Karrera Menu Panel IP Information
Replacing a Menu Panel processor will require resetting all Menu Panel IP addresses. This
includes the actual Menu Panel IP addresses, as well as the addresses the Menu Panel uses
to communicate with the Video Processor Frame and Control Panel (DPOPs).
Video Processor Frame Maintenance
Video Processor Frame NV Memory
GV K-Frame XP system non-volatile memory (NV Memory) contains Engineering, Suite, and
User configuration data, and also has data for all the effects registers. This data is stored as
files on the Video Processor Frame Solid State Drive, and is loaded on bootup. Errors in this
data could cause system problems, which may be overcome, perhaps only temporarily, by
clearing the NV Memory.
Note: You should have backup copies of your configuration and E-MEM files
compatible with your current software version so they can be restored after
the NV Memory is cleared.
Clear NV RAM for Control Panel and Frame
Use the following procedure from the Menu Panel or Menu on PC running the Menu Panel
application that operates with the updated Video Processor Frame.
Note: A new Menu Panel or PC that has not been used with the switcher
system will need to be configured as a Control Surface Node before it can
operate with a switcher system.
1 From the Installer menu, select the System button and then the device to be cleared.