External Interfaces
278
Configure Ethernet Tally Ports
Additionally, tally is supported via GPO connections.
Note: Serial tally is not supported for switcher systems due to the vast
amount of data being transmitted.
Configure Ethernet Tally Ports
1 In the menu, select Eng Setup, Ports & Devices, Tally Ports.
2 In one of the ports, select the IP Address data pad.
3 Enter the client IP Address in the pop-up keypad and select
Enter.
About Editor Ports
Editor Ports connect to external editor, using up to four of the eight RS422 Ports.
Button descriptions:
•
RS422 Port Select / Status – The button for the port currently assigned to the selected
item will be highlighted. Touching
None clears the port assignment.
•
Editor Name – Touching this button opens an alphanumeric keypad used to give the
Editor a descriptive name.
•
Unassign Editor – Clears the selected serial port’s assignment.
•
Baud Rate / Parity – Serial port settings are selected with these buttons. The
Set Default button returns the settings to the factory defaults.