Basic Configuration
Switcher System Timing
256
IP Switcher System 771-0741-01 IP I/O Board Auto-timing Window, by Format (Hz) (continued)
Frame Operating
Mode
ST 2110-20
ST 2022-6
ST TICO 2022-6
1080pA 59.94/60 -9 µs, -16 line/-4 µs, 0 lines -5.7 µs, -16 lines/-4 µs, 0 lines -5 µs, -18 lines/-3 µs, -2 lines
1080pA 50 -15 µs, -16 line/-7 µs, 0 lines -13 µs, -13 lines/-7 µs, 0 lines -13 µs, -15 lines/-7 µs, -2 lines
2160p 59.94/60 -2.0 µs, -9 lines/-7.0 µs 0 lines N/A N/A
2160p 50 -3.0 µs, -9 lines/-9.0 µs, 0 lines N/A N/A
SDI Auto-timing Specifications
When conversion is on, video signals are automatically frame-synced.
SDI Timing Windows
Frame Operating Mode
Standard SDI
Conversion Board (In Bypass
Mode)
525i 29.97 +/- 8.69 µs
-63.4 µs/0
625i 50 +/- 8.88 µs
-64 µs/0
720p/59.94/60 +/- 2.02 µs
-22.2 µs/0
720p/50 +/- 4.23 µs
-26.6 µs/0
1080i-1080psf/29.97/30 +/- 5.73 µs
-29.6
µs
/0
1080i-1080psf/25 +/- 8.68 µs
-35.5
µs
/0
1080psf 23.98/24 +/- 9.43 µs
-37.0
µs
/0
1080pA 59.94/60 +/- 2.87 µs
-14.8
µs
/0
1080pA 50 +/- 4.34 µs
-17.7
µs
/0
1080pB 59.9/60 +/- 9.44 µs
-29.6
µs
/0
1080pB 50 +/- 12.39 µs
-35.5
µs
/0