Trigger Examples
The follow 3 examples show the steps necessary to use the output,
transient or memory trigger system:
Output Trigger Example:
:SYSTem:CONFigure:TRIGger:INPut:MODE MANual
:TRIGger:OUTPut:SOURce BUS
:OUTPut:STATe:TRIGgered <bool>|OFF|ON
:INITiate:IMMediate:NAME OUTPut
*TRG
Transient Trigger Example:
:SYSTem:CONFigure:TRIGger:INPut:MODE MANual
:SOURce:FREQuency:TRIGgered 60
:SOURce:VOLTage:LEVel:TRIGgered:AMPLitude 100
:TRIGger:TRANsient:SOURce BUS
:INITiate:IMMediate:NAME TRANsient
*TRG
Memory Trigger Example:
:SYSTem:CONFigure:TRIGger:INPut:MODE MANual
:MEMory:TRIGgered 1
:TRIGger:MEMory:SOURce BUS
:INITiate:IMMediate:NAME MEMory
*TRG