EasyManua.ls Logo

Hakko Electronics V Series - 1: n Connection

Hakko Electronics V Series
332 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix 6 Universal Serial Communications App6-9
1 : n Connection
* When you go to [Comm. Parameters] under the [System Setting], to [Main2], and check [Execute 4
Wire Control], 1 : n connection is not available.
Wiring
Perform wiring as shown below.
<2-wire system>
- When TC485 is used:
- When TC485 is not used:
Install jumpers between +RD/+SD and RD/SD.
<4-wire system>
Twist-shielded Cables
- Use twist-shielded cables provided by the following manufacturers.
FG
+SD
SD
+RD
RD
FG
RDA
RDB
SDA
SDB
FG
+SD
SD
+RD
RD
FG
+SD
SD
+RD
RD
SG SGSGSG
V+TC485 (SW: Lower)
Terminating resistance
(ON)
* Use twist-shielded cables.
V+TC485 (SW: Lower) V+TC485 (SW: Lower)
General-purpose
computer
Signal
Name
Signal
Name
Signal
Name
Signal
Name
Terminating resistance
(OFF)
Terminating resistance
(OFF)
FG
+SD
SD
+RD
RD
FG
RDA
RDB
SDA
SDB
FG
+SD
SD
+RD
RD
FG
+SD
SD
+RD
RD
SG SGSGSG
V+TC485 (SW: Upper)
Terminating resistance
(ON)
* Use twist-shielded cables.
V+TC485 (SW: Upper) V+TC485 (SW: Upper)
General-purpose
computer
Signal
Name
Signal
Name
Signal
Name
Signal
Name
Terminating resistance
(OFF)
Terminating resistance
(OFF)
Manufacturer Type
Hitachi Cable CO-SPEV-SB(A) 3P × .3SQ
Mitsubishi Cable SPEV-SB-MPC 3P × .3SQ

Table of Contents