Appendix 1 PLC2Way App1-17
Indirect Memory Designation
It is possible to have access to the PLC2 memory using the indirect memory designation as a macro
command.
In this section, the indirect designation of the PLC2 memory is explained.
The internal user memory ($u) is used for the indirect memory designation.
Designating the indirect memory
PLC2 memory
- Memory type
Depends on the PLC model.
Refer to “Available Memory” in “Chapter 2” to “Chapter 33” when setting.
- Port number
Set the port number of the PLC connected at the MJ port.
User Log Read for YOKOGAWA’s PLC
The user log set with YOKOGAWA’s PLC “FA-M3/FA-M3R” connected at the MJ port can be read
using the macro command TEMP_CTL.
Macro
[TEMP_CTL]
This macro command controls the operation set in the memory addresses starting from the one
specified for F0 for the number of words specified for F1.
Usable Devices
TEMP_CTL: Temperature controller/PLC2Way control function
TEMP_CTL F0 F1
Return data: Data stored from PLC2Way to V7 series
*2 Set “0” for CPU No. 1.
*3 The registration number is stored in special register Z105.
*4 If there is no user log in the “n + 2” memory or there is an error in communications, [1] is stored.
n + 0 Model (03) Memory type
n + 1 Memory number (address)
n + 2 00 Bit designation
n+3 00 Port
15 8 7 0
<0 to 65535>
n + 0 Model (83) Memory type
n + 1 Memory number (address) upper
n + 2 Memory number (address) lower
n + 3 00 Bit designation
n + 4 00 Port number
15 8 7 0
<65536 and above>
PLC Memory Internal Memory Constant (Words) Memory Card
Indirect
Designation
F0
F1
F0 (= $u n) F1
n n+1 n+2 n+3 n+4 n+5 n+6 n+7 n+8 n+9 n+10 n+11 Words
User log
registration
number read
Port
number
CPU No. 1
*1
(0 to 3)
Command
1
Registration
number
*2
−−−−−−−−3
Latest user
log read
Port
number
CPU No. 1
*1
(0 to 3)
Command
0
Header
0: Normal
1: Error
*3
Year Month Day Hour Minute Second
Main
code
Sub
code
3
(ASCII) (DEC)
“n”th user log
read
Port
number
CPU No. 1
*1
(0 to 3)
Command
1 to 63
Header
0: Normal
1: Error
*3
Year Month Day Hour Minute Second
Main
code
Sub
code
3
(ASCII) (DEC)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hakko Electronics V Series and is the answer not in the manual?

Hakko Electronics V Series Specifications

General IconGeneral
BrandHakko Electronics
ModelV Series
CategoryMonitor
LanguageEnglish

Related product manuals