ID2000 Series Industrial Code Reader User Manual
53
Parameter
Description
Polling Lighting Enable
After enabling this parameter, the light source will turn on.
Figure 9-4 Single Mode
Multiple Mode
Note
In multiple mode, the device supports trigger parameters like software trigger, external
trigger, etc., does not support stopping polling via the external trigger.
The rule for multiple-mode polling is that the polling is started from the polling parameter
with Best Polling Group Idx, and then execute other polling parameters you selected in
turn. For example, if the Param3 is the Best Polling Group Idx and Param1, Param2,
Param4 and Param5 are enabled, the polling order is Param3 > Param1 > Param2 >
Param4 > Param5.
Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Image Setting Polling Mode, and select Multiple as Polling Enable.
3. Set Polling Time and Polling Period according to actual demands.
Polling Time is used to determine whether the polling is finished or not, and it ranges from
100 to 2147482.
Polling Period is whole period from Param1 to Param8, and it ranges from 1 to 5000.
4. Select 2 to 8 sets of parameters (e.g. Param1 and Param2) from Polling Param, and
enable Polling Param Enable to let them take effect.
5. Set parameters participating the polling like Polling Exposure Time, Polling Gain, Polling
Gamma, etc. according to actual demands.