ID2000 Series Industrial Code Reader User Manual
59
Figure 9-12 Global Auto Focus
2. Click in the live view window, and click it again to stop acquisition and make sure
there is an image in the window.
3. Select the focus mode in Auto Config:
Full Auto: In this mode, the device will automatically change parameters like focus
position, exposure, gain, Gamma and light source when adjusting focus.
Motor Only: In this mode, the device will change focus position only when adjusting focus.
Auto and Restore: In this mode, the device will automatically change parameters like
focus position, exposure, gain, Gamma and light source when adjusting focus, and keep
focus position and restore other parameters after completing focus adjustment.
4. Click Execute in Focus Mode, and the device starts to adjust focus automatically.
Note
Focus related parameters cannot be configured during auto focus process, and after the
process, parameters can be configured again.
5. (Optional) Select the position parameter from Focus Position, and click Execute in Focus
Position Save to save the focus position after adjusting focus.