EasyManua.ls Logo

HikRobot ID2000 Series - Page 84

HikRobot ID2000 Series
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ID2000 Series Industrial Code Reader User Manual
75
Steps
1. Click I/O Control Settings Input Trigger Mode.
2. Select On as Trigger Mode.
3. Select Software as Trigger Source.
4. Click Execute in Trigger Source to send trigger commands.
You can also enter Auto Trigger Time, and then enable Enable Auto Trigger to let the client
software automatically send trigger signal to device according to the interval you set.
Figure 9-29 Set and Execute Software Trigger Mode
Set and Execute Hardware Trigger Mode
Steps
1. Click I/O Control Settings Input Trigger Mode.
2. Select On as Trigger Mode.
3. Select the specific line as Trigger Source according to actual demands.
Note
For the vari focal device (type I, type II and type III devices), you can select customized lines
as Trigger Source. Refer to section Line Mode Settings for specific settings.
4. Set Debounce Time and Line Out Trigger In Polarity according to actual demands.
Note
When selecting Rising Edge or Falling Edge as Line Out Trigger In Polarity, you can set
Trigger Delay.
When selecting Level High or Level Low as Line Out Trigger In Polarity, you can set Start
Delay Time and End Delay Time according to actual demands.

Table of Contents

Related product manuals