ID2000 Series Industrial Code Reader User Manual
77
2. Select On as Trigger Mode.
3. Select TCP Start as Trigger Source.
4. Set following parameters according to actual demands.
TCP Trigger Port: It sets the host port of TCP trigger.
TCP Start Trigger Text: It sets the trigger text of TCP start, and it is Start by default.
Set and Execute UDP Trigger Mode
UDP start specifies the UDP server as the source for the trigger signal. When the server
receives the specified string text, the trigger signal will be outputted.
Steps
1. Go to I/O Control Settings Input Trigger Mode.
2. Select On as Trigger Mode.
3. Select UDP Start as Trigger Source.
4. Set following parameters according to actual demands.
UDP Trigger Port: It sets the host port of UDP trigger.
UDP Start Trigger Text: It sets the trigger text of UDP start, and it is Start by default.
Set and Execute Serial Port Trigger Mode
Serial start specifies the serial port as the source for the trigger signal. When the serial port
receives the specified string text, the trigger signal will be outputted.
Steps
1. Go to I/O Control Settings Input Trigger Mode.
2. Select On as Trigger Mode.
3. Select Serial Start as Trigger Source.
4. Set Serial Baudrate, Serial Data Bits, Serial Parity, and Serial Stop Bits.
5. Set Serial Start Trigger Text that configures the trigger text of serial port start, and it is
Start by default.
Set and Execute USB Trigger Mode
Steps
1. Go to I/O Control Settings Input Trigger Mode.
2. Select On as Trigger Mode.
3. Select USB Start as Trigger Source.
4. Set USB Baudrate, USB Data Bits, USB Parity, USB Stop Bits, and USB Start Trigger Text
according to actual demands.