3) Click Draw Region, and draw a quadrilateral in the preview window.
8.
Oponal: Draw the maximum size/minimum size for targets. Only the targets in the size ranging
from maximum size to minimum size will trigger line crossing detecon.
1) Click Max. Size/Min. Size.
2) Draw an area in preview window.
3) Click Stop Drawing.
9.
Oponal: Select Target of Interest as Human Body or Vehicle to discard alarms which are not
triggered by human body or vehicle.
10. Set the arming schedule. Refer to
Congure Arming Schedule .
11. Set linkage
acons. Refer to Congure Linkage Acons .
12. Click Apply.
6.4.4 Region
Exing Detecon
Region exing detecon detects objects that exit from a predened virtual region.
Steps
1. Go to Smart Analysis → Smart Event Sengs → Perimeter Protecon .
2. Select a camera.
3. Click Region
Exing.
Figure 6-14 Region Exing Detecon
4. Check Enable Region Exing Detecon.
5.
Oponal: Check Save VCA Picture to save the captured region exing detecon pictures.
6. Oponal: Check Enable AI by Device. The device will analyze the video, cameras only transmit
video stream.
7. Follow these steps to set the
detecon rules and detecon areas.
1) Select Arming Region. Up to 4 regions are selectable.
2) Set
Sensivity. The higher the value is, the more easily the detecon alarm will be triggered.
Its range is [0-100].
Network Video Recorder User Manual