3-7
OPERATING THE ENGINE
MDAA-01-085EN
Password Input Screen
3
Slow Idle
1
LOCK position
2
Starting in Cold Weather
Preheating
1. Confirm that pilot control shut-off lever (1) is in the LOCK
position.
2. Turn engine control dial (3) to around the middle
between the L and H position.
3. Sound the horn to alert bystanders.
4. Insert key (2) to the key switch. Turn it to ON position.
5. "Wait-screen (nothing is displayed)" is displayed on the
monitor for 2 seconds. Regardless of pilot control shut-
off lever (1) position, the engine can not be cranked
during this moment.
6. When the Password Input screen is displayed on the
monitor, input the password. Unless the numeric keypad
function (ignition block system) is activated, this screen
is not displayed.
IMPORTANT: When required to activate the numeric
keypad function (ignition block system), consult your
authorized dealer.
MDAA-01-295
MDC1-01-502
M1P1-01-068