7-82
MAINTENANCE
Bleed Air from the Fuel System
Air in the fuel system may make the engine hard to start or
make it run irregularly.
After draining water and sediment from the fuel filter,
replacing the fuel filter, cleaning the fuel solenoid pump
strainer or running the fuel tank dry, be sure to bleed the air
from the fuel system.
Main Points to Bleed Air
This machine is equipped with a fuel solenoid pump.
d
CAUTION: Fuel leaks may lead to fires.
1. Check that fuel cock (1) on the bottom of the fuel tank is
opened.
2. Turn the key switch ON and hold it in that position for
approx. 3 minutes. Thereby, the fuel solenoid pump
operates, starting to bleed air.
3. After the main filter is filled with fuel, hold the key switch
in the ON position for 30 seconds.
4. Start the engine. Check the fuel supply system for fuel
leaks.
IMPORTANT: Even if air is not thoroughly bled, do not
hold the key switch in the ON position for more than 5
minutes. In case air is not thoroughly bled, first return
the key switch to the OFF position. After waiting for
more than 30 seconds, turn the key switch ON again.
Failure to do so may cause damage to the fuel solenoid
pump and/or discharging the batteries.
1
MDAA-07-007
Main Filter
Main Filter
MDC1-07-046
MDC1-07-047

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi ZAXIS 120-6 class and is the answer not in the manual?

Hitachi ZAXIS 120-6 class Specifications

General IconGeneral
BrandHitachi
ModelZAXIS 120-6 class
CategoryExcavators
LanguageEnglish

Related product manuals