<Sysname> display poe pse 7
PSE ID : 7
Slot No. : 2
PSE Model : LSBMPOEGV48TP
PSE Status : Enabled
PSE Preempted : No
Power Priority : Low
Current Power : 130 W
Average Power : 20 W
Peak Power : 240 W
Max Power : 200 W
Remaining Guaranteed Power : 120 W
PSE CPLD Version : 100
PSE Software Version : 200
PSE Hardware Version : 100
Legacy PD Detection : Disabled
Power Utilization Threshold : 80
PSE Power Policy : Disabled
PD Power Policy : Disabled
PD Disconnect-Detection Mode : DC
# (Distributed devices in IRF mode.) Display detailed information about PSE 7.
<Sysname> display poe pse 7
PSE ID : 7
Chassis : 1
Slot No. : 2
SSlot No. : 0
PSE Model : LSBMPOEGV48TP
PSE Status : Disabled
PSE Preempted : No
Power Priority : Low
Current Power : 0 W
Average Power : 0 W
Peak Power : 0 W
Max Power : 200 W
Remaining Guaranteed Power : 200 W
PSE CPLD Version : 100
PSE Software Version : 200
PSE Hardware Version : 100
Legacy PD Detection : Disabled
Power Utilization Threshold : 80
PSE Power Policy : Disabled
PD Power Policy : Disabled
PD Disconnect Detection Mode : DC
Table 26 Command output
Field
Description
PSE ID ID of the PSE.

Table of Contents