Page #320 background image
310
display kernel exception
Use display kernel exception to display kernel thread exception information.
Syntax
Centralized devices in standalone mode:
display kernel exception show-number [ offset ] [ verbose ]
Distributed devices in standalone mode/centralized devices in IRF mode:
display kernel exception show-number [ offset ] [ verbose ] [ slot slot-number [ cpu cpu-number ] ]
Distributed devices in IRF mode:
display kernel exception show-number [ offset ] [ verbose ] [ chassis chassis-number slot
slot-number [ cpu cpu-number ] ]
Views
Any view
Predefined user roles
network-admin
Parameters
show-number: Specifies the number of kernel exceptions to display, in the range of 1 to 10.
offset: Specifies the offset between the starting exception and the latest exception, in the range of 0
to 9. The default value is 0.
verbose: Displays detailed information. If you do not specify this keyword, the command displays
brief information.
slot slot-number: Specifies an MPU by its slot number. If you do not specify this option, the
command displays kernel thread exception information for the active MPU. (Distributed devices in
standalone mode.)
slot slot-number: Specifies an IRF member device by its ID. If you do not specify this option, the
command displays kernel thread exception information for the master device. (Centralized devices in
IRF mode.)
chassis chassis-number slot slot-number: Specifies an MPU on an IRF member device. If you do
not specify this option, the command displays kernel thread exception information for the global
active MPU. (Distributed devices in IRF mode.)
cpu cpu-number: Specifies a CPU by its number. (Centralized devices in IRF mode/distributed
devices in IRF or standalone mode.)
Usage guidelines
If an exception occurs to a running kernel thread, the system automatically records the exception
information.
Examples
# Display brief information about the latest kernel thread exception.
<Sysname> display kernel exception 1
----------------- Exception record 1 -----------------
Description : Oops[#0]
Recorded at : 2013-05-01 11:16:00.823018
Occurred at : 2013-05-01 11:16:00.823018
Instruction address : 0x4004158c
Thread : comsh (TID: 16306)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork MSR3012 and is the answer not in the manual?

HPE FlexNetwork MSR3012 Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork MSR3012
CategoryNetwork Router
LanguageEnglish

Related product manuals