141
poe disconnect
Use poe disconnect to configure a PD disconnection detection mode.
Use undo poe disconnect to restore the default.
Syntax
poe disconnect { ac | dc }
undo poe disconnect
Default
The PD disconnection detection mode is ac.
Views
System view
Predefined user roles
network-admin
Parameters
ac: Specifies the PD disconnection detection mode as ac.
dc: Specifies the PD disconnection detection mode as dc.
Usage guidelines
If you change the PD disconnection detection mode while the device is running, the connected PDs
are powered off.
Examples
# Set the PD disconnection detection mode to dc.
<Sysname> system-view
[Sysname] poe disconnect dc
Related commands
display poe pse
poe enable
Use poe enable to enable PoE on a PI.
Use undo poe enable to disable PoE on a PI.
Syntax
poe enable
undo poe enable
Default
PoE is disabled on a PI.
Views
PI view
PoE profile view
Predefined user roles
network-admin

Table of Contents