315
0xe2be5f50: 02 be 5f 90 00 00 00 08 02 be 5f e0 00 00 00 08
0xe2be5f60: 02 be 5f 80 00 ac 1b 14 00 00 00 00 00 00 00 00
0xe2be5f70: 05 b4 5f 90 02 be 5f e0 00 00 00 30 02 be 5f e0
0xe2be5f80: 02 be 5f c0 00 ac 1b f4 00 00 00 00 02 45 00 00
0xe2be5f90: 00 03 00 00 00 00 00 00 02 be 5f e0 00 00 00 30
0xe2be5fa0: 02 be 5f c0 00 ac 1b 14 61 f1 2e ae 02 45 00 00
0xe2be5fb0: 02 44 b3 74 02 be 5f d0 00 00 00 30 02 be 5f e0
0xe2be5fc0: 02 be 60 60 01 74 ff f8 00 00 00 00 00 00 08 00
0xe2be5fd0: 02 be 5f f0 00 e8 93 7e 02 be 5f f8 02 be 5f fc
0xe2be5fe0: 00 00 00 00 00 00 00 00 00 00 00 00 02 be 60 18
0xe2be5ff0: 02 be 60 10 00 e9 65 98 00 00 00 58 00 00 2a 4f
0xe2be6000: 02 be 60 10 00 00 00 00 00 00 00 00 02 be 60 68
0xe2be6010: 02 be 60 40 00 e8 c6 a0 00 00 11 17 00 00 00 00
0xe2be6020: 02 be 60 40 00 00 00 00 00 00 00 00 02 be 60 98
0xe2be6030: 02 27 00 00 00 00 00 00 00 00 00 00 02 be 60 68
0xe2be6040: 02 be 60 60 00 00 00 01 00 00 b0 30 02 be 60 98
0xe2be6050: 00 00 00 04 02 21 00 00 00 00 00 00 01 e9 00 00
0xe2be6060: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0xe2be6070: 00 00 00 00 00 00 00 00 02 be 66 c0 02 be 66 d0
0xe2be6080: 02 be 61 e0 00 00 00 02 00 00 00 00 02 be 61 70
0xe2be6090: 00 00 00 00 02 21 00 00 05 8d 34 c4 05 7d 92 44
Call trace:
Function Address = 0x8012a4b4
Function Address = 0x8017989c
Function Address = 0x80179b30
Function Address = 0x80127438
Function Address = 0x8012d734
Function Address = 0x80100a00
Function Address = 0xe0071004
Function Address = 0x8016ce0c
Function Address = 0x801223a0
Table 66 Command output
Field
Description
Recorded at Time when the reboot was recorded on the MPU, with microsecond precision.
Occurred at Time when the reboot occurred, with microsecond precision.
Reason Reboot reason.
Thread Name and number of the rebooted kernel thread.
Context Context where the reboot occurred.
Chassis Number of the IRF member device that triggered the reboot..
Slot
Slot number of the MPU that triggered the reboot.. (Distributed devices in IRF
or standalone mode.)
IRF member ID of the device that triggered the reboot. (Centralized devices in
IRF mode.)
Fixed to 0. (Centralized devices in standalone mode.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork MSR3012 and is the answer not in the manual?

HPE FlexNetwork MSR3012 Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork MSR3012
CategoryNetwork Router
LanguageEnglish

Related product manuals