395
Parameters
slot slot-number: Specifies a card by its slot number. If you do not specify a card, the command
displays IPv6 NetStream template information for the active MPU. (Distributed devices in standalone
mode.)
slot slot-number: Specifies an IRF member device by its member ID. If you do not specify a member
device, this command displays IPv6 NetStream template information for the master device.
(Centralized devices in IRF mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The
chassis-number argument represents the member ID of the IRF member device. The slot-number
argument represents the slot number of the card. If you do not specify a card, this command displays
IPv6 NetStream template information for the global active MPU. (Distributed devices in IRF mode.)
Usage guidelines
IPv6 NetStream templates vary by aggregation mode. This command displays IPv6 NetStream
template information for all the configured aggregation modes.
Examples
# Display IPv6 NetStream template information.
<Sysname> display ipv6 netstream template
Flow template refresh frequency : 20
Flow template refresh interval : 30 min
Active flow templates : 4
Created flow templates : 4
AS outbound template:
Template ID : 3293
Field count : 14
Field type Field length (bytes)
---------------------------------------------------------------------------
Flows 4
Out packets 8
Out bytes 8
First forwarded 4
Last forwarded 4
Source AS 4
Destination AS 4
Input Interface Index 4
Output Interface Index 4
IP protocol version 1
Direction 1
Sampling algorithm 1
PAD 1
Sampling interval 4
AS inbound template:
Template ID : 3292
Field count : 14
Field type Field length (bytes)
---------------------------------------------------------------------------
Flows 4