Peer mode: unspec, peer poll interval: 10
Offset: 0.0000ms, roundtrip delay: 0.0000ms, dispersion: 15937ms
Root roundtrip delay: 0.0000ms, root dispersion: 0.0000ms
Reachabilities:0, sync distance: 15.938
Precision: 2^10, version: 4, source interface: Not specified
Reftime: 00000000.00000000 Thu, Feb 7 2036 6:28:16.000
Orgtime: d17cbb21.0f318106 Tue, May 17 2011 9:15:13.059
Rcvtime: 00000000.00000000 Thu, Feb 7 2036 6:28:16.000
Xmttime: 00000000.00000000 Thu, Feb 7 2036 6:28:16.000
Roundtrip delay samples: 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Offset samples: 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Filter order: 0 1 2 3 4 5 6 7
Total sessions: 1
Table 14 Command output
Field
Description
Clock source
IPv6 address of the clock source. If this field displays
::
, the IPv6
address of the NTP server has not been resolved successfully.
Clock stratum
Stratum level of the NTP server, which determines the clock
precision. The value is in the range of 1 to 16. A lower stratum
level represents higher clock accuracy. A stratum 16 clock is not
synchronized and cannot be used as a reference clock.
Clock status
Status of the clock source corresponding to this association:
• configured—The association was created at the CLI.
• dynamic—The association is established dynamically.
• master—The clock source is the primary time server of the
current system.
• selected—The clock source has survived the clock selection
algorithm.
• candidate—
The clock source is the candidate reference
source.
• sane—The clock source has passed authentication and will
be used as the reference source.
• insane—The clock source has not passed authentication, or
it has passed authentication but will not
be used as the
reference source.
• valid—
The clock source is valid, which means the clock
source meets the following requirements:
ï‚¡ It has been authenticated and synchronized.
ï‚¡ Its stratum level is valid.
ï‚¡ Its root delay and root dispersion values are within their
ranges.
• invalid—The clock source is invalid.
• unsynced—The clock source has not been synchronized or
the value of the stratum level is invalid.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork MSR3012 and is the answer not in the manual?

HPE FlexNetwork MSR3012 Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork MSR3012
CategoryNetwork Router
LanguageEnglish

Related product manuals