88
Field
Description
Clock status
Status of the clock source corresponding to this association:
configuredTh
e association was created by a
configuration command.
dynamicThe association is established dynamically.
masterThe clock source is the primary time server of the
current system.
selectedThe clock source has survived the clock selection
algorithm.
candidate
The clock source is the candidate reference
source.
saneThe clock source has passed authentication and will
be used as the reference source.
insaneThe clock source has not passed authentication, or
has passed authentication but will not be used as the
reference source.
valid
The clock source is valid, which means the clock
source meets the following requirements:
It has been authenticated and synchronized.
Its stratum level is valid.
Its root delay and root dispersion values are within their
ranges.
invalidThe clock source is invalid.
unsyncedThe clock source has not been synchronized or
the value of the stratum level is invalid.
Reference clock ID
Reference clock ID of the NTP server:
If the reference clock is the local clock, the value of this field
is related to the value of the Clock stratum field:
When the value of the Clock stratum field is 0 or 1, this
field displays LOCL.
When the Clock stratum field has another value, this
field displays the IP address of the local clock.
If the reference clock is the clock of another device on the
network, this field displays the IP address of the device. If the
device supports IPv6, this field displays the MD5 digest of
the first 32 bits of the IPv6 address of the device. If this field
displays INIT
, the local device has not established a
connection with the NTP server.
VPN instance
VPN instance to which the NTP server belongs. If the NTP server
is in a public network, the field displays
Not specified
.
Local mode
Operation mode of the local device:
unspecThe mode is unspecified.
activeActive mode.
passivePassive mode.
clientClient mode.
serverServer mode.
broadcastBroadcast or multicast server mode.
bclientBroadcast or multicast client mode.
local poll interval
Polling interval of the local device
, in seconds. The value
displayed is a power of 2. For example, if the displayed value is 6,
the poll interval of the local device is 26, or 64 seconds.