HPE ProLiant DL385 Gen11 - Removing and replacing a type-o storage controller; About this task; Procedure

HPE ProLiant DL385 Gen11
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removing and replacing a type-o storage controllerRemoving and replacing a type-o storage controller
About this taskAbout this task
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
CAUTION:CAUTION:
The port blank provides EMI shielding and helps maintain proper thermal status inside the server. Do not operate the server
when a port blank is removed without the corresponding I/O port option installed.
CAUTION:CAUTION:
Before replacing a DIMM, backplane, expansion card, riser board, or other similar PCA components due to a perceived
hardware error, make sure first that the component is firmly seated in the slot.
When installing the replacement component:
Observe antistatic precautions.
Handle the PCA only along the edges.
Do not touch the components and connectors on the PCA.
Do not bend or flex the PCA.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.