4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel.
8. If the server is in the rear 4 LFF drive configuration, remove the rear 4 LFF drive cage .
9. Do one of the following:
a. If removing the type-o controller from Slot 21, remove the primary riser cage.
b. If removing the type-o controller from Slot 22, remove the secondary riser cage.
10. Disconnect the storage cables from the type-o controller.
11. Remove the type-o storage controller:
a. Rotate the locking pin to the open (vertical) position (callout 1).
b. Slide the controller out of the bay (callout 2).
ResultsResults
To replace the component, reverse the removal procedure.
Removing the Removing the boot deviceboot device security cover from the NS204i-u + secondary low-profile riser security cover from the NS204i-u + secondary low-profile riser
cagecage
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm.