19. Connect each power cord to the power source.
20. Power up the server .
21. Properly dispose of the old battery.
For more information about proper battery disposal, contact an authorized reseller or an authorized service provider.
ResultsResults
The installation is complete.
Heatsink replacementHeatsink replacement
SubtopicsSubtopics
Removing the heatsinkRemoving the heatsink
Installing the heatsinkInstalling the heatsink
Removing the heatsinkRemoving the heatsink
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-20 Torx screwdriver available.
About this taskAbout this task
WARNING:WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to
cool before touching them.
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm.