6.3.8 Setting Inverter Parameters
SUN2000 is displayed for V300R001C00.
Procedure
Step 1 Choose Maintenance > Connect Device and set access parameters.
● Method 1: Click Auto. Search to connect to the solar inverter.
● Method 2: Click Add Devices, set access parameters, and click Add Devices.
Figure 6-45 Setting access parameters
Parameter Description
Device type Set this parameter to SUN2000.
Connection mode ● If the solar inverter uses the MBUS for
communication, set this parameter to MBUS.
● If the solar inverter uses RS485 for communication,
set this parameter to the COM port connected to
the solar inverter.
Address Set this parameter to the communication address of
the solar inverter.
Step 2 Choose Monitoring > Inverter > Running Param. and set running parameters,
click Submit.
Before setting the running parameters of the solar inverter, ensure that the DC
side of the solar inverter is energized.
----End
SmartLogger3000
User Manual 6 WebUI Operations
Issue 10 (2022-08-20) Copyright © Huawei Technologies Co., Ltd. 120