7 Device Maintenance
7.1 Routine Maintenance
Ensure that the SmartLogger is free from strong electromagnetic interference.
Ensure that the SmartLogger is away from heat sources.
Regularly clean the SmartLogger.
Regularly check that cables are secured.
7.2 Troubleshooting
No.
Fault Cause Suggestions
1 The
SmartLogge
r cannot be
powered on.
1. The DC output power cable for
the power adapter is not
connected the 12V IN port of the
SmartLogger.
2. The power cable is not connected
to the AC power input port of the
power adapter.
3. The AC input power cable is not
connected to the AC socket.
4. The power adapter is faulty.
5. The SmartLogger is faulty.
1. Connect the DC output power
cable for the power adapter to
the 12V IN port of the
SmartLogger.
2. Check that the power cable is
connected to the AC power input
port of the power adapter.
3. Check that the power cable is
connected to the AC socket.
4. Replace the power adapter.
5. Contact the dealer or Huawei
technical support.
SmartLogger3000
User Manual 7 Device Maintenance
Issue 10 (2022-08-20) Copyright © Huawei Technologies Co., Ltd. 230

Table of Contents

Other manuals for Huawei SmartLogger3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartLogger3000 and is the answer not in the manual?

Huawei SmartLogger3000 Specifications

General IconGeneral
BrandHuawei
ModelSmartLogger3000
CategoryData Loggers
LanguageEnglish

Related product manuals