Figure 6-63 Importing conguration
Step 2 Set access parameters and click Add Devices.
Figure 6-64 Setting access parameters
Parameter Description
Device Type The value can be IEC104 Device 1 to IEC104 Device
5.
Select a value based on the imported conguration
le. For example, if iec104_equip_custom_1.cfg is
imported, select IEC104 Device 1.
IP address Set this parameter to the IP address of the IEC104
device.
Common address Set this parameter to the common address of the
IEC104 device.
Address Set this parameter to the communications address of
the IEC104 device.
Step 3 Set device monitoring parameters and click Submit.
SmartLogger3000
User Manual 6 WebUI Operations