INTELLIGENT ACTUATOR
Appendix
Other Parameters
No. Parameter name
Default value
(Reference)
Input range Unit Remarks
49 Panel 7-segment
display data type
0 0 to 9 0: Display controller status
1: Display motor current indicator
The current pattern of each axis is displayed instead of
“ready status” or “program run number.”
“Minimum indicator-displayed axis number” (far-right
column) is specified by “Other parameter No. 50.”
(Main application version 0.09 or later)
0 < Motor current to rating ratio (%) 25
25 < Motor current to rating ratio (%) 50
50 < Motor current to rating ratio (%) 75
75 < Motor current to rating ratio (%) 100
100 < Motor current to rating ratio (%) 150
150 < Motor current to rating ratio (%) 200
200 < Motor current to rating ratio (%)
2: Display user information number (U001 to U999)
The user information number is displayed instead of
“ready status” or “program run number” only when the
user information number is not “0.” “Global integer
variable number for specifying user information number”
is specified by “Other parameter No. 50.”
(Main application version 0.09 or later)
50 Auxiliary specification
for panel 7-segment
display data type
0 -99999999
to
99999999
* Refer to the Remarks field for “Other parameter No. 49.”
51
to
100
(For expansion) 0 (Main application version 0.52 or later/F-ROM 32-Mbit
version only)
101
to
200
(For expansion) 0 (Main application version 0.52 or later/F-ROM 32-Mbit
version only)