■ AGC function
The AGC (auto gain control) controls receiver gain to
produce a constant audio output level even when the
received signal strength varies greatly.
The transceiver has 3 preset AGC characteristics (time
constant: fast, mid, slow) for non-FM modes.
TheFMmodeAGCtimeconstantisfixedas‘FAST’
(0.1 seconds) and AGC time constant cannot be
changed.
D Selecting the preset value
q Select any non-FM mode.
w Push [AGC] (MF5) several times to select AGC fast,
AGC medium (MID) or AGC slow.
•Holddown
AGCVR
for 1 second to turn the AGC
function OFF.
D Adjusting the AGC time constant
q Select any non-FM mode.
w Push
AGCVR
, then rotate [AGC] control to adjust
the AGC time constant.
•[AGCVR]indicatorabovetheswitchlightsgreen.
D Setting the AGC time constant preset value
q Select any non-FM mode.
w Hold down [AGC] (MF5) for 1 second to enter AGC
set mode.
e Push [AGC]
(MF5) several times to select FAST
time constant.
r Rotate the main dial to set the desired time con-
stant for ‘AGC FAST.’
•AGCtimeconstantcanbesetbetween0.1to8.0sec-
onds (depends on mode) or turned OFF.
•Holddown[DEF]
F-4
for 1 second to select a default
value.
t Push [AGC] (MF5) to select medium time constant.
y Rotate the main dial to set the desired time con-
stant for ‘AGC MID.’
•AGCtimeconstantcanbesetbetween0.1to8.0sec-
onds (depends on mode) or turned OFF.
•Holddown[DEF]
F-4
for 1 second to select a default
value.
u Push [AGC] (MF5) to select slow time constant.
i Rotate the main dial to set the desired time con-
stant for ‘AGC SLOW.’
•AGCtimeconstantcanbesetbetween0.1to8.0sec-
onds (depends on mode) or turned OFF.
•Holddown[DEF]
F-4
for 1 second to select a default
value.
o Select another non-FM mode. Repeat steps e to
i if desired.
!0 Push
EXIT/SET
toexittheAGCsetmodescreen.
5-12
5
FUNCTIONS FOR RECEIVE
Mode Default Selectable AGC time constant
0.3 (FAST)
0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0,
SSB 2.0 (MID)
2.5, 3.0, 4.0, 5.0, 6.0
6.0 (SLOW)
0.1 (FAST)
0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0,
CW 0.5 (MID)
2.5, 3.0, 4.0, 5.0, 6.0
1.2 (SLOW)
RTTY
0.1 (FAST)
0.1, 0.2, 0.3, 0.5, 0.8, 1.2, 1.6, 2.0,
PSK
0.5 (MID)
2.5, 3.0, 4.0, 5.0, 6.0
1.2 (SLOW)
3.0 (FAST)
0.3, 0.5, 0.8, 1.2, 1.6, 2.0, 2.5, 3.0,
AM 5.0 (MID)
4.0, 5.0, 6.0, 7.0, 8.0
7.0 (SLOW)
FM 0.1(FAST) Fixed
• Selectable AGC time constant (unit: sec.)