3-14
3
BASIC OPERATIONS
D Programming the user band edge
q Select the Others set mode and select the “Beep
(Band Edge)” option.
w Rotate the main dial to select either the “ON (User)”
or “ON (User) & TX Limit” setting.
•[BAND]appearsabove
F-5
.
e Push [BAND]
F-5
to open the band edge screen.
r Push [Y ]
F-1
or [Z]
F-2
to select the desired
band edge.
•Push[t u]
F-3
to select the upper and lower band
edge frequency entry cell.
•Push[INS](MF6)toinsertanewblankbandedgeline.
•Holddown[DEL](MF7)for1secondtodeletethese-
lected band edge line.
t Push
F-INP
ENT
, and then input the desired fre-
quency with the keypad.
•Push
GENE
•
to input decimal point (“.”) between the
MHz and kHz digits.
•Programeachchannelfromlefttorightandeachfre-
quency must be higher than the preceding frequency.
•Thefrequencythatisduplicated,oroutofanamateur
band, cannot be programmed.
•If you want to return the band edge frequencies to
their default (initial) value, hold down [DEF]
F-4
for
1 second.
The band edge initialize screen appears as shown
below, then hold down [OK]
F-6
for 1 second to initial-
ize all band edge frequency settings.
y Push
F-INP
ENT
to set the input frequency.
u Push
EXIT/SET
toexitthesetmode.
Appears when “ON (User)” or “ON (User) & TX Limit” is
selected.
• Band edge screen