Parameter List
‑73‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
AC‑06 0xAC06 AI2 measured
voltage 2
‑10.000 V to +10.000 V 8 V In real time "
AC‑06
"
on
page 384
AC‑07 0xAC07 AI2 displayed
voltage 2
‑10.000 V to +10.000 V 8 V In real time "
AC‑07
"
on
page 384
AC‑08 0xAC08 AI3 measured
voltage 1
‑10.000 V to +10.000 V 2 V In real time "
AC‑08
"
on
page 384
AC‑09 0xAC09 AI3 displayed
voltage 1
‑10.000 V to +10.000 V 2 V In real time "
AC‑09
"
on
page 385
AC‑10 0xAC0A AI3 measured
voltage 2
‑10.000 V to +10.000 V 8 V In real time "
AC‑10
"
on
page 385
AC‑11 0xAC0B AI3 displayed
voltage 2
‑10.000 V to +10.000 V 8 V In real time "
AC‑11
"
on
page 385
AC‑12 0xAC0C AO1 measured
voltage 1
‑10.000 V to +10.000 V 2 V In real time "
AC‑12
"
on
page 386
AC‑13 0xAC0D AO1 target voltage
1
‑10.000 V to +10.000 V 2 V In real time "
AC‑13
"
on
page 386
AC‑14 0xAC0E AO1 measured
voltage 2
‑10.000 V to +10.000 V 8 V In real time "
AC‑14
"
on
page 386
AC‑15 0xAC0F AO1 target voltage
2
‑10.000 V to +10.000 V 8 V In real time "
AC‑15
"
on
page 387
AC‑16 0xAC10 AO2 measured
voltage 1
‑10.000 V to +10.000 V 2 V In real time "
AC‑16
"
on
page 387
AC‑17 0xAC11 AO2 target voltage
1
‑10.000 V to +10.000 V 2 V In real time "
AC‑17
"
on
page 387
AC‑18 0xAC12 AO2 measured
voltage 2
‑10.000 V to +10.000 V 8 V In real time "
AC‑18
"
on
page 388
AC‑19 0xAC13 AO2 target voltage
2
‑10.000 V to +10.000 V 8 V In real time "
AC‑19
"
on
page 388
AC‑20 0xAC14 PT100 measured
voltage 1
0.000 V to 3.3 V 0.44 V In real time "
AC‑20
"
on
page 388
AC‑21 0xAC15 PT100 displayed
voltage 1
0.000 V to 3.3 V 0.44 V In real time "
AC‑21
"
on
page 389
AC‑22 0xAC16 PT100 measured
voltage 2
0.000 V to 3.3 V 2.16 V In real time "
AC‑22
"
on
page 389
AC‑23 0xAC17 PT100 displayed
voltage 2
0.000 V to 3.3 V 2.16 V In real time "
AC‑23
"
on
page 389
AC‑24 0xAC18 PT1000 measured
voltage 1
0.000 V to 3.3 V 1.136 V In real time "
AC‑24
"
on
page 390
AC‑25 0xAC19 Voltage 1 display
on the PT1000
0.000 V to 3.3 V 1.136 V In real time "
AC‑25
"
on
page 390
AC‑26 0xAC1A PT1000 measured
voltage 2
0.000 V to 3.3 V 2.122 V In real time "
AC‑26
"
on
page 390
AC‑27 0xAC1B Voltage 2 display
on the PT1000
0.000 V to 3.3 V 2.122 V In real time "
AC‑27
"
on
page 391