USER MANUAL
INTEL® FALCON™ 8+ UAS
© 2018 Intel Corporation. All rights reserved 160
Calibration
No calib on
payload
found
Timeout: Not
able to read a
payload calibra-
tion from camera
EEPROM within
15 seconds after
start-up. Usually
happening with
new Payloads /
Payloads never
calibrated on an
Intel® Falcon™ 8+
UAV.
Possibly bad
yaw alignment.
Run payload
calibration.
Calibration
Invalid
payload
calib -
please
recali-
brate!
Payload calibra-
tion invalid. The
reason could be
that less than 3
IMUs were avail-
able during the
calibration pro-
cess.
Possibly bad
yaw alignment.
Run payload
calibration
again.
Calibration
No payload
installed
or payload
config
faulty
Payload could
not be found.
Payload not
working.
Check Pay-
load connec-
tion; re-
initiate cam-
era type
EEPROM.
Calibration
Payload
calibration
not
successful!
Payload calibra-
tion failed.
Possibly bad
yaw alignment.
Run payload
calibration
again. If the
message is
displayed
again, contact
the support.
Table 3.13: AscTec Trinity Control Unit system warnings (continued)
CATEGOR
Y
WARNING/
ERROR
MEANING CONSEQUENC
E
POSSIBLE
FIXES