Chapter 13: Alarm and event setup
TruVision NVR 11 User Manual 111
software’s alarm monitor port. Up to three alarm hosts can be set. For each alarm
host, the default port is 5001, 5002, and 5003.
3. Click Apply to save the settings.
4. Click Exit to return to live view.
Intrusion integration alarm reporting
The recorder includes an alarm receiver software module for intrusion integration. This
permits SIA and XSIA events to be reported to the recorder from Interlogix intrusion
panels via IP and to be linked to recorder actions.
The following Interlogix panels are supported:
ATS Master (EMEA only)
Advisor Advanced (EMEA only)
NetworX panels
Up to three intrusion panels can be set up in the recorder. Each panel can report up to
32 intrusion zones (a zone is an intrusion panel input).
The panels must support the SIA or XSIA reporting protocol. They can report the
following alarm types to the recorder:
An arming event
A disarming event
An alarm event that has an “A” as a second character in the SIA/XSIA code
A heartbeat alarm
In the intrusion panel set up the recorder as a normal monitoring station. Use OH
version 3 so that the data format is understood by the recorder.
To set up an alarm panel in the recorder:
1. From the menu toolbar, click Alarm & Event Setup > Intrusion Panel Setup.
2. In the Intrusion Panel Setup window, enter the required settings.

Table of Contents

Other manuals for Interlogix TruVision series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix TruVision series and is the answer not in the manual?

Interlogix TruVision series Specifications

General IconGeneral
DimensionsVaries by model
WeightVaries by model
TypeNVR
Channels4/8/16/32
CompressionH.264, H.265
Network InterfaceGigabit Ethernet
Power Supply100 to 240 VAC
Humidity10% to 90% non-condensing
Hard Drive BaysUp to 8

Related product manuals