Process data
Operating and Programming 113
Byte
Bit
Category
Description
Type
Comment
3
.0
Global Signals
Start
BOOL
Starts all RollerDrive of the
network user
3
.1
Global Signals
StartInvers
BOOL
Starts all RollerDrive of the
network user in the opposite
direction
3
.2
Global Signals
NormalStop
BOOL
Stops all zones of the
network user
3
.3
Global Signals
EmergencyStop
BOOL
Stops all RollerDrive of the
network user immediately
3
.4
Global Signals
AlternateSpeed
BOOL
Switches all zones of the
network user to an
alternative speed
3
.5
Global Signals
InverseDirection
BOOL
Switches the direction of
rotation of all zones of the
network user
3
.6
Global Signals
GlobalError
BOOL
Error in a zone of the
network user
3
.7
Global Signals
Reserve
BOOL