EasyManuals Logo

Interroll MultiControl User Manual

Interroll MultiControl
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Description of the control programs
Operating and Programming 23
5.1 ZPA Single Release
For Single Release the removal is done in individual zones („ZPA Single Release 1 Zone“ to „ZPA
Single Release 4 Zone“).
Free RollerDrive connections can be used as slave motors according to the table (PII Motor
States).
Timer
ID
Description
Default [ms]
T1
Connection monitoring
200
T2
Internal conveyed items monitoring
4000
T3
Follow-up time RollerDrive
5000
T4
Error reset
1000
The parameter "Timer 1 - Connection monitoring" should not be changed.
In addition to the explanations of the control programs, the corresponding process
images are listed below.

Table of Contents

Other manuals for Interroll MultiControl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interroll MultiControl and is the answer not in the manual?

Interroll MultiControl Specifications

General IconGeneral
Power Supply24 VDC
Rated Voltage24 VDC
Storage Temperature-20 °C to +70 °C
Communication ProtocolsEthernet/IP, PROFINET, EtherCAT, CANOpen
Number of Channels4
Weight0.5 kg