7 – 25
7.5
7.5.3.2 Setting HDG SENSOR Adjustment
As HDG SENSOR is selected in Own Ship Course equipment, set HDG SENSOR adjustment as follows.
• In case of HDG or HDT data send from HDG SENSOR
As output data from HDG SENSOR is adjusted by HDG SENSOR, the setting of radar menu is OFF.
Procedures
1. Press the
SUB
MENU
key to open the SUB MENU.
2. Press the
9
key four times to open the INIT SETTING #4 menu.
3. Press the
1
key to select "HDG SENSOR CORRECTION".
4. Press the
1
key to select "OFF".
5. Press the
ENT
key to confirm the setting.
Exit
6. Press the
SUB
MENU
key.
• In case of HDM data send from HDG SENSOR
As output data fro HDG SENSOR isn't adjusted by HDG SENSOR, enter adjust data written the chart.
Procedures
1. Press the
SUB
MENU
key to open the SUB MENU.
2. Press the
9
key four times to open the INIT SETTING #4 menu.
3. Press the
1
key to select "ON" on the "HDG SENSOR CORRECTION",
and press the
ENT
key to confirm the setting.
4. Press the
2
key to select "CORRECT VALUE", and enter adjust
data written on the chart by using numeric key (
0
to
9
).
5. Press the
ENT
key to confirm the setting.
Exit
6. Press the
SUB
MENU
key.