7 – 4
7.1
7
7.1.2.3 Sensor Test
This test is used to check signals from the scanner unit.
Procedures
1. Follow procedures 1 to 3 in subsection 7.1.2.1.
The DIAGNOSTIC MENU appears.
2. Press the
3
key to open the SENSOR TEST menu.
"OK" is displayed when the bearing pulses (BP and BZ) are input in the display unit.
Exit
3. Press the
SUB
MENU
key.
Sensor Test
SENSOR TEST
0. PREVIOUS MENU
SAFETY SWITCH ON
BEARING PULSE (BP) OK
BEARING PULSE (BZ) OK
To close this menu, Press (SUB MENU) key.
7.1.2.4 Line Test
This test is used to check the communication status with optional equipment.
Procedures
1. Follow procedures 1 to 3 in subsection 7.1.2.1.
The DIAGNOSTIC MENU appears.
2. Press the
4
key to open the LINE TEST menu.
"ON" appears when communication or connection has been established.
Exit
3. Press the
SUB
MENU
key.
Line Test
LINE TEST
0. PREVIOUS MENU
NSK ON
UART1 ON
UART2 OFF
ARPA ON
To close this menu, Press (SUB MENU) key.