WARNING: Warnhinweis: Bei der Befestigung in vertikaler Position muss ein EX
3200- oder EX 4200-Switch-Gehäuse so ausgerichtet werden, dass das vordere
Bedienfeld des Switch-Gehäuses nach unten zeigt.
Related Topics Mounting an EX 3200 or EX 4200 Switch on a Wall on page 69
Ramp Warning
WARNING: When installing the switch, do not use a ramp inclined at more than 10
degrees.
Waarschuwing Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden.
Varoitus Älä käytä sellaista kaltevaa pintaa, jonka kaltevuus ylittää 10 astetta.
Attention Ne pas utiliser une rampe dont l'inclinaison est supérieure à 10 degrés.
Warnung Keine Rampen mit einer Neigung von mehr als 10 Grad verwenden.
Avvertenza Non usare una rampa con pendenza superiore a 10 gradi.
Advarsel Bruk aldri en rampe som heller mer enn 10 grader.
Aviso Não utilize uma rampa com uma inclinação superior a 10 graus.
¡Atención! No usar una rampa inclinada más de 10 grados
Varning! Använd inte ramp med en lutning på mer än 10 grader.
Related Topics General Safety Guidelines and Warnings on page 130
AC Power Electrical Safety Guidelines on page 154
General Electrical Safety Guidelines on page 153
Laser and LED Safety Guidelines and Warnings on page 143
Installation Instructions Warning on page 146
Grounded Equipment Warning on page 163
Power and Electrical Warnings
General Electrical Safety Guidelines on page 153
AC Power Electrical Safety Guidelines on page 154
In Case of Electrical Accident on page 155
Power Disconnection Warning on page 156
Multiple Power Supplies Disconnection Warning on page 156
152 Ramp Warning
Complete Hardware Guide for EX 3200 and EX 4200 Switches

Table of Contents

Other manuals for Juniper EX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX Series and is the answer not in the manual?

Juniper EX Series Specifications

General IconGeneral
SeriesEX Series
CategorySwitch
LayerLayer 2/3
Operating SystemJunos OS
ManagedYes
ACLsYes
Port DensityVaries by model
Power over Ethernet (PoE)Available on some models
Virtual ChassisSupported on some models
Form FactorFixed configuration, Modular
Switching CapacityVaries by model
Forwarding RateVaries by model
Power SupplyVaries by model (AC or DC, redundant options available)
ManagementCLI, Web UI, SNMP
RedundancyPower supply, fan, Virtual Chassis
LatencyVaries by model
Jumbo FramesSupported
VLAN SupportYes
MAC Address Table SizeVaries by model
QoSYes
Energy EfficiencyEEE (802.3az)
DimensionsVaries by model
WeightVaries by model
Operating Temperature0° to 45° C
Storage Temperature-40° to 70° C
Humidity5% to 90% non-condensing