To Previous Page IconTo Previous Page
Loading...
8. Replace the protective cover over the input terminal block.
9. Ensure that the power supply is fully inserted and latched securely in the chassis.
10. Repeat Steps 4 through step 9 for any remaining power supply.
11. Remove the tape from the switch handle of the circuit breaker on the panel board that services the
DC circuit, and switch the circuit breaker to the ON (|) position.
12. Verify that the OK/FAIL LED is lit green and on steadily.
RELATED DOCUMENTATION
SRX4600 Power System | 35
Configuring the SRX4600 Services Gateway
You must perform the initial configuration of the device through the console port.
Before you begin, set the following parameter values in the console server or the management host:
Baud rate—9600
Flow control—None
Data—8
Parity—None
Stop bits—1
DCD state—Disregard
To configure the device from the console:
1. Connect the console port (CON), located on the front panel of the services gateway to a laptop or PC
by using the provided RJ-45 cable and RJ-45 to DB-9 serial port adapter.
2. Log in as the root user. There is no password.
login: root