Replacing the SRX4600 Services Gateway Fan Module
IN THIS SECTION
Removing the SRX4600 Services Gateway Fan Module | 87
Installing the SRX4600 Services Gateway Fan Module | 88
Each fan module is a field-replaceable unit (FRU) installed in the rear panel of the SRX4600 Services
Gateway. You can remove and replace the fan modules without powering off the services gateway or
disrupting services gateway functions.
NOTE: All the fan modules must be installed and operational for optimal functioning of the
services gateway.
Removing the SRX4600 Services Gateway Fan Module
You can remove a fan module without powering off the services gateway or disrupting services gateway
functions.
NOTE: Once you remove the faulty fan module, make sure you install a working fan module
within two minutes.
Ensure that you have the following tools and parts available:
Phillips (+) screwdriver, number 1
An antistatic bag or an antistatic mat
A replacement fan module
Electrostatic discharge (ESD) grounding strap