146 Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
10 Triggers
• When the time range (><) qualifier is selected, the Entry knob sets the upper
time range value.
Pulse width
trigger > qualifier
time set softkey
• When the greater than (>) qualifier is selected, the Entry knob sets the
oscilloscope to trigger on a pulse width greater than the time value displayed
on the softkey.
• When the time range (><) qualifier is selected, the Entry knob sets the lower
time range value.
Pattern Trigger
The Pattern trigger identifies a trigger condition by looking for a specified pattern.
This pattern is a logical AND combination of the channels. Each channel can have
a value of 0 (low), 1 (high), or don't care (X). A rising or falling edge can be
specified for one channel included in the pattern. You can also trigger on a hex
bus value as described on "Hex Bus Pattern Trigger" on page 148.
1 Press the [Trigger] key.
2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to
select Pattern.
3 For each analog or digital channel you want to include in the desired pattern,
press the Channel softkey to select the channel.
This is the channel source for the 0, 1, X, or edge condition. As you press the
Channel softkey (or rotate the Entry knob), the channel you select is highlighted
in the Pattern = line directly above the softkeys and in the upper-right corner of
the display next to "Pat".
Adjust the trigger level for the selected analog channel by turning the Trigger
Level knob. Press the [Digital] key and select Thresholds to set the threshold level
for digital channels. The value of the trigger level or digital threshold is
displayed in the upper-right corner of the display.
4 For each channel you select, press the Pattern softkey; then, turn the Entry knob
to set the condition for that channel in the pattern.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision 2000 X Series and is the answer not in the manual?

Keysight Technologies InfiniiVision 2000 X Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision 2000 X Series
CategoryTest Equipment
LanguageEnglish

Related product manuals