I2C/SPI Triggering and Serial Decode 24
Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide 357
The Set all Bits softkey will set all bits in the data string to the value of the 0 1 X
softkey.
SPI Serial Decode
To set up the oscilloscope to capture SPI signals, see "Setup for SPI Signals" on
page 351.
To set up SPI serial decode:
1 Press [Serial] to display the Serial Decode Menu.
2 Press the Word Size softkey; then, turn the Entry knob to select the number of
bits in a word.
3 Press the Bit Order softkey; then turn the Entry knob to select the bit order, most
significant bit first (MSB) or least significant bit first (LSB), used when
displaying data in the serial decode waveform and in the Lister.
4 If the decode line does not appear on the display, press the [Serial] key to turn it
on.
5 If the oscilloscope is stopped, press the [Run/Stop] key to acquire and decode
data.
NOTE
For SPI decode information see "SPI Serial Decode" on page 357.
NOTE
For SPI triggering setup see "SPI Triggering" on page 355.
NOTE
If the setup does not produce a stable trigger, the SPI signal may be slow enough that the
oscilloscope is AutoTriggering. Press the [Mode/Coupling] key, then press the Mode softkey
to set the trigger mode from Auto to Normal.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision 2000 X Series and is the answer not in the manual?

Keysight Technologies InfiniiVision 2000 X Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision 2000 X Series
CategoryTest Equipment
LanguageEnglish

Related product manuals