Sequencing 3
Keysight M8195A Revision 2 – Arbitrary Waveform Generator User’s Guide 115
3.5.1 Auto
After having executed all loops, the sequencer advances to the next element
automatically. No external interaction is required for advancement.
The sequencer repeats the current element until it receives the correct advancement
event. After having received the advancement event, the current element is played to
the end before switching to the next one.
After having executed all loops the sequencer stops and plays the last value of the
current element. This last value can be specified in the corresponding sequence vector
(default value is the offset voltage). After having received the advancement event, the
sequencer starts playing the next element. When receiving the advancement event
before having played all repetitions, all repetitions will be played before moving to the
next element.
After having executed an element once, the sequencer stops and plays the last value of
the element. This last value can be specified in the corresponding sequence vector
(default value is the offset voltage). After having received the next advancement event
the process is repeated until having executed all loops of the current element. Then the
execution advances to the next element.
Sequencer Controls are used to influence the sequencer. So they can control the
waveform generation.