EasyManua.ls Logo

Keysight M8195A - Trigger[:Sequence][:Start]:Advance:hwdisable[:State][?] 0|1|OFF|ON

Keysight M8195A
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 General Programming
190 Keysight M8195A Revision 2 Arbitrary Waveform Generator User’s Guide
Example
Command
:TRIG:BEG:HWD ON
Query
:TRIG:BEG:HWD?
6.8.18 :TRIGger[:SEQuence][:STARt]:ADVance:HWDisable[:STATe][?]
0|1|OFF|ON
Command
:TRIG:ADV:HWD[?]
Long
:TRIGger:ADVance:HWDisable[?]
Parameters
0|1|OFF|ON
Parameter Suffix
None
Description
Set or query the hardware input disable state for the advancement function. When
the hardware input is disabled, an advancement event can only be generated using
the :TRIGger[:SEQuence][:STARt]:ADVance[:IMMediate] command. When the
hardware input is enabled, an advancement event can be generated by command or
by a signal present at the trigger or event input.
Example
Command
:TRIG:ADV:HWD 0
Query
:TRIG:ADV:HWD?

Table of Contents