General Programming 6
Keysight M8195A Revision 2 Arbitrary Waveform Generator User’s Guide 213
Example
Command:
OUTP:FILT:HRAT:TYPE NYQ
6.13.13 :OUTPut[1|2|3|4]:FILTer:HRATe:SCALe[?] <scale>|MINimum|MAXimum
Command
: OUTP:FILT:HRAT:SCAL[?]
Long
: OUTPut:FILTer:HRATe:SCALe[?]
Parameters
<scale>|MINimum|MAXimum
Parameter Suffix
None
Description
Set or get the FIR filter scaling factor for a channel to be used when the Sample Rate
Divider for the Extended Memory is 2. The range is between 0 and 1.
Example
Command:
OUTP:FILT:HRAT:SCAL 0.9
6.13.14 :OUTPut[1|2|3|4]:FILTer:HRATe:DELay[?] <delay>|MINimum|MAXimum
Command
:OUTP:FILT:HRAT:DEL[?]
Long
:OUTPut:FILTer:HRATe:DELay[?]
Parameters
<delay>|MINimum|MAXimum
Parameter Suffix
[s|ms|us|ns|ps]
Description
Set or get the FIR filter delay for a channel to be used when the Sample Rate Divider
for the Extended Memory is 2. The range is -100ps..+100ps. The delay value has only
effect for filter types NYQuist and LINear.
The command form modifies the FIR filter coefficients according to the set delay
value.
Example
Command:
OUTP:FILT:HRAT:DEL 10ps