General Programming 6 
 
Keysight M8195A Revision 2 – Arbitrary Waveform Generator User’s Guide    233 
 
6.18.6  [:SOURce]:STABle:DYNamic:[STATe][?] OFF|ON|0|1 
 
Use this command to enable or disable dynamic mode.  
If dynamic mode is switched off, segments or sequences can only be switched in 
program mode, that is signal generation must be stopped. In arbitrary mode use 
TRACe[1|2|3|4]:SELect to switch to a new segment. In sequence mode use 
[:SOURce]:STABle:SEQuence:SELect to switch to a new sequence.  
If dynamic mode is switched on, segments or sequences can be switched 
dynamically when signal generation is active. The next segment or sequence is either 
selected by the command [:SOURce]:STABle:DYNamic:SELect or by a signal fed into 
the dynamic port of the M8197 module. The external input values select sequence 
table entries with corresponding indices.  
When the dynamic mode for segments or sequences is active, set the sequence table 
entry to be executed next..